NEW! Smart
Fieldmeter¨ Digital Products
|
Meter, Probe |
Frequency
Range |
Field
Strength Range |
Notes |
|
Smart
Fieldmeter¨ Digital Meter: Model: RFP-05 |
50 KHz - 18 GHz (depending on the probe used). |
0.2-800 V/m (depending on the probe used) |
Stocked Model. Supports
all current and future probe models.
Probes are not included. |
|
Probe: PI-03 |
3 MHz - 18 GHz Correction factors at frequencies (MHz): 3, 10, 100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500, 13000, 13500, 14000,
15000, 16000, 17000, 18000. |
0.8 – 800 V/m |
Stocked Model. |
|
Probe: PI-02 |
2 MHz - 12.5 GHz Correction factors at frequencies (MHz): 2, 10,100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500. |
0.5 – 800 V/m |
Non-stocked Model.
Consult EMCTD for lead time. |
|
Probe: PI-01 |
0.2 MHz - 3 GHz Correction factors at frequencies (MHz): 0.2, 0.5, 1, 10,
100, 1000, 1900, 2400, 3000. |
0.2 – 600 V/m |
Stocked Model. |
|
Probe: PI-01V |
900-1900 MHz. Dual GSM band. Selective frequency range. Correction factors for the frequency range (MHz): 700-2100. |
0.4 – 400 V/m |
Stocked Model. |
|
Probe PI-01 LF Option |
50 KHz – 3 GHz |
|
Extended low frequency limit for Kit 1. |
Notes:
1. The RFP-05
meter set includes: meter in hard case with accessories (AC/DC charger, table
tripod, mounting clip, meter-probe SMA cable, SD card) and Users Manual.
New! Smart Fieldmeter¨
Digital Product Kits
|
Meter, Probe |
Frequency
Range |
Field
Strength Range |
Notes |
|
Kit 3D Meter: RFP-05 Probe: PI-03 Field Gauge ª |
3 MHz - 18 GHz Correction factors at frequencies (MHz): 3, 10, 100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500, 13000, 13500, 14000,
15000, 16000, 17000, 18000. |
0.8 – 800 V/m |
Stocked Model. |
|
Kit 2D Meter: RFP-05 Probe: PI-02 Field Gauge ª |
2 MHz - 12.5 GHz Correction factors at frequencies (MHz): 2, 10,100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500. |
0.5 – 800 V/m |
Non-stocked Model.
Consult EMCTD for lead time. |
|
Kit 1D Meter: RFP-05 Probe: PI-01 Field Gauge ª |
0.2 MHz - 3 GHz Correction factors at frequencies (MHz): 0.2, 0.5, 1, 10,
100, 1000, 1900, 2400, 3000. |
0.2 – 600 V/m |
Stocked Model. |
|
Kit 4D Meter: RFP-05 Probe: PI-01V |
900-1900 MHz. Dual GSM band. Selective frequency range. Correction factors for the frequency range (MHz): 700-2100. |
0.4 – 400 V/m |
Stocked Model. |
Notes:
1. For probe variants, please, see the Table above.
2. Every Kit includes: meter in hard case with accessories
(AC/DC charger, table tripod, mounting clip, meter-probe SMA cable, SD card)
and Users Manual with Calibration Certificate. Field Gauge ¨ is included with
Kit1D, Kit2D, Kit3D.
Accessories
Selection Table for Smart Fieldmeter¨ Digital Products
|
Name |
Description |
Notes |
|
Cable:
Meter-Probe |
SMA/SMA 4-6
ft. |
Included in
all kits. |
|
Data Cable |
Cable 2.5 mm
plugs on both ends, length 3-5 ft. |
Optional. |
|
Table Tripod |
6Ó Nonmetal
Tripod |
Included in
all kits. |
|
ODLK-01 |
Optically Decoupled Link Kit. Includes Data Cable and TTL/RS232
bidirectional converter with optical Isolator. Serial isolated
RS232 output. |
Optional. |
|
FOLK-01 |
Fiber Optic Link Kit. Includes two
bidirectional RS232/Optic converters and 10-meter (30Ô) bi-line fiber
optic cable. |
Makes seamless fiber optic
connection of RFP-05 meter with PC for data streaming. Requires ODLK-01. #1. Optional
cable -20 m. #2. Optional
cable 50 m. |
|
RS232-USB
Adapter |
Adapter to
convert serial RS232 signal to USB for computers without RS232 port. |
Optional. |
|
Field Gauge ª
FG-01 |
Allows
verification of all Smart Fieldmeter¨ Digital broadband probes in seconds.
Operates with PI-01, PI-02, PI-03 probes and their optional variants. |
Stocked Model. Recommended
for all systems. |
|
IR Remote |
IR remote
controls Smart Fieldmeter¨ Digital from the distance. |
Optional. |
|
FC-01 |
Portable
frequency counter with frequency range 30 MHz-2.8 GHz. |
Measures
pulsed GSM and cell phone signals with RF pulse duration longer than 250
usec. |
Smart
Fieldmeter¨ Product Kits
|
Meter, Probe |
Frequency Range |
Field Strength
Range |
Notes |
|
Kit 3 Meter: RFP-04HF Probe: PI-03 Field Gauge ¨ |
3 MHz - 18 GHz Correction factors at frequencies (MHz): 3, 10, 100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500, 13000, 13500, 14000,
15000, 16000, 17000, 18000. |
0.8 – 800* V/m |
Stocked Model. |
|
Kit 2 Meter: RFP-04HF Probe: PI-02 Field Gauge ¨ |
2 MHz - 12.5 GHz Correction factors at frequencies (MHz): 2, 10,100, 1000,
1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500. |
0.5 – 800* V/m |
Non-stocked Model.
Consult EMCTD about lead time. |
|
Kit 1 Meter: RFP-04CE Probe: PI-01 Field Gauge ¨ |
0.2 MHz - 3 GHz Correction factors at frequencies (MHz): 0.2, 0.5, 1, 10,
100, 1000, 1900, 2400, 3000. |
0.2 – 500* V/m |
Stocked Model. |
|
Kit 4 Meter: RFP-04 Probe: PI-01V |
900-1900 MHz Correction factors for the frequency range (MHz): 700-2100. |
0.4 – 400* V/m |
Stocked Model.
Dual GSM band. Selective
frequency range. |
|
Kit 1 LF Option |
50 KHz – 3 GHz |
|
Extended low frequency limit for Kit 1. |
Notes:
1. (*)Exact upper field limit is specified for each unit.
2. Every Kit includes: meter, probe in hard case with
accessories (table tripod, mounting clip, meter-probe SMA cable, remote monitor
output cable) and Users Manual with calibration certificate. Field Gauge ¨ is
included with Kit1, Kit2, Kit3.
Accessories
Selection Table for Smart Fieldmeter¨
Product Kits
|
Name |
Description |
Notes |
|
|
Cable: Meter-Probe |
SMA/SMA 4-6 ft. |
Stocked, Standard |
|
|
Cable: Remote Monitor Output |
3.5 mm one end - dual banana another end, 6 ft. |
Stocked, Special |
|
|
Table Tripod |
6Ó Nonmetal Tripod |
Stocked, Standard. |
|
|
PCLK-01-1 |
Low Cost PC Link Kit 120 samples/sec. RS232 isolated serial data link for
one channel with one isolating input module and display software. |
Full system for data streaming and display on PC for one
RFP-04 unit. |
|
|
FOLK-01 |
Low Cost Fiber Optic Link for PCLK-01-1. Fiber
optic cable 10 meters. #1. Optional cable -20 m. #2. Optional cable 50 m. |
Makes full system for data streaming and display on PC for
one RFP-04 unit with fiber optic connection (requires
PCLK-01-1). |
|
|
DL-01-2 |
Portable data logging DMM with PC Link (20 samples/sec). Logging memory
43,000 data points. Logging time
interval 0.05 sec.-12 hours. |
DMM with Optically Decoupled RS232 Link. Can also perform
real time PC streaming 1 sample/sec. |
|
|
DL-02 |
Portable data logging DMM with PC Link. Has 33 readings
memory for data storage operated by the user. |
DMM with Optically Decoupled RS232 Link. Can also perform real time PC streaming 1 sample/sec. |
|
|
DL-03 |
Portable data logger with RS 232 output. Logging memory 8,192 data
points. Logging time interval is
set to 0.88 sec. until memory is full (2 hours), then it is doubled, etc. |
Battery logging operation for 1 year. |
|
|
DL-04 |
Portable data logger with RS 232 output. Logging memory 32,768 data
points. Logging time interval
from 2 sec. to 12 hours, programmable. |
Battery logging operation for 1 year. |
|
|
FC-01 |
Portable frequency counter with frequency range 30 MHz-2.8
GHz. |
Measures pulsed GSM and cell phone
signals with RF pulse duration longer than 250 usec. |
|
Omnifield
Antenna¨
Product Kits
|
Model |
Frequency
Range |
Field Strength
Range |
Notes |
|
OFA-S Active Broadband
Isotropic Antenna |
30 MHz - 3 GHz Antenna factors (AF) for the frequency range (MHz): 30-3000. |
3 mV/m-300 V/m |
Stocked Model. Operates with any spectrum analyzer. |
Notes:
1. Every Kit includes: antenna unit OFA-S, power unit
PU-5S, custom 5 ft. ferrite beaded RF cable, AC/DC plug-in charger, table
tripod, mounting accessories, Users Manual with calibration certificate, in
rugged plastic storage case with custom foam insert.
Services Selection Table
|
Name |
Description |
Notes |
|
Calibration. PI-01, PI-01V, PI-02, PI-03 and PI-04 probes with RFP-05 and RFP-04 meters. |
Calibration of probe with meter: Linearity, Isotropicity and
Frequency Correction Factors. Recommended once per two ears. UK NPL (NIST) traceable. |
For RFP-05 systems: Meter presence is
desirable for confidence. For RFP-04 systems: Meter must be present for calibration. |
|
Repair. |
Repair and calibration of meter with probe. UK NPL (NIST) traceable |
Free during the warranty period. |