Smart
Fieldmeter¨ Products
|
Meter, Probe |
Frequency Range |
Field Strength Range |
Time Constants |
Notes |
|
Kit 3 Meter: RFP-04HF Probe: PI-03 Field Gauge ¨ |
3 MHz - 18 GHz Correction factors at frequencies (MHz): 3, 10, 100,
1000, 1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500, 13000, 13500,
14000, 15000, 16000, 17000, 18000. |
0.8 – 800* V/m |
50 ms, 2 s, 14 s |
Stocked Model.
Extended calibration
certificate. |
|
Kit 2 Meter: RFP-04HF Probe: PI-02 Field Gauge ¨ |
2 MHz - 12.5 GHz Correction factors at frequencies (MHz): 2, 10,100,
1000, 1200, 1900, 2400, 3000, 3700, 5700, 8000, 10500, 12500. |
0.5 – 800* V/m |
50 ms, 2 s, 14 s |
Non-stocked Model. Consult EMCTD about lead time. Extended calibration certificate. |
|
Kit 1 Meter: RFP-04CE Probe: PI-01 Field Gauge ¨ |
0.2 MHz - 3 GHz Correction factors at frequencies (MHz): 0.2, 0.5, 1,
10, 100, 1000, 1900, 2400, 3000. |
0.2 – 500* V/m |
50 ms, 2 s, 14 s |
Stocked Model. Extended calibration certificate. |
|
Kit 4 Meter: RFP-04 Probe: PI-01V |
900-1900 MHz Correction factors for the frequency range (MHz): 700-2100. |
0.4 – 400* V/m |
50 ms, 2 s, 14 s |
Stocked Model.
Dual GSM band. Selective
frequency range. Extended calibration
certificate. |
|
Kit 1 LF Option |
50 KHz –
3 GHz |
|
|
Extended low frequency limit for Kit 1. |
|
Kit 3 LF Option |
1 MHz - 18 GHz |
|
|
Extended low frequency limit for Kit 3. |
|
Kit 2 LF Option |
0.5 MHz - 12.5
GHz |
|
|
Extended low frequency limit for Kit 2. |
|
Kit 1 UL Option |
|
1.0 – 800*
V/m |
|
Extended upper field strength limit for Kit 1. |
|
Kit 1, Kit 2, Kit 3 and Kit 4 F Option |
|
|
5 ms, 2 s, 14 s |
Faster response time for pulsed signals. |
|
Kit 1, Kit 2, Kit 3 and Kit 4 E Option |
|
|
|
Environmental Model.
Contact EMCTD for specification details. |
*Exact upper field limit is specified for each unit.
Omnifield
Antenna¨ Products (NEW!)
|
Model |
Frequency Range |
Field Strength Range |
Notes |
|
OFA-S Active Broadband Isotropic Antenna |
30 MHz - 3 GHz Antenna factors (AF) for the
frequency range (MHz): 30-3000. |
1 mV/m-300 V/m |
Stocked Model. Operates with any spectrum
analyzer. |
Accessories
Selection Table
|
Name |
Description |
Notes |
|
Cable: Meter-Probe |
SMA/SMA 4-6 ft. |
Stocked, Standard |
|
Cable: Remote Monitor Output |
3.5 mm one end - dual banana
another end, 6 ft. |
Stocked, Special |
|
Tripod |
6Ó Nonmetal Tripod |
Stocked, Standard. |
|
PCLK-01-1 |
Low Cost PC Link Kit 120
samples/sec. RS232 isolated
serial data link for one channel with one isolating input module and display software. |
Full system for data
streaming and display on PC for one RFP-04 unit. |
|
FOLK-01 |
Low Cost Fiber Optic Link for PCLK-01-1. Fiber optic cable 10 meters. #1. Optional cable -20 m. #2. Optional cable 50 m. |
Makes full system for data
streaming and display on PC for one RFP-04 unit with fiber optic connection (requires
PCLK-01-1). |
|
DL-01-2 |
Portable data logging DMM
with PC Link (20 samples/sec).
Logging memory 43,000 data points.
Logging time interval 0.05 sec.-12 hours. |
DMM with Optically Decoupled
RS232 Link. Can also perform real time PC streaming 1 sample/sec. |
|
DL-02 |
Portable data logging DMM
with PC Link. Has 33 readings memory for data storage operated by the user. |
DMM with Optically Decoupled
RS232 Link. Can also perform real time
PC streaming 1 sample/sec. |
|
DL-03 |
Portable data logger with RS
232 output. Logging memory 8,192
data points. Logging time interval
is set to 0.88 sec. until memory is full (2 hours), then it is doubled, etc. |
Battery logging operation
for 1 year. |
|
DL-04 |
Portable data logger with RS
232 output. Logging memory
32,768 data points. Logging time
interval from 2 sec. to 12 hours, programmable. |
Battery logging operation
for 1 year. |
|
FC-01 |
Portable frequency counter
with frequency range 30 MHz-2.8 GHz. |
Measures
pulsed GSM and cell phone signals with RF pulse duration longer than 250
usec. |
Services Selection Table
|
Name |
Description |
Notes |
|
Calibration Standard (for legacy PI-01 units). |
Calibration of meter with probe. UK NPL (NIST) traceable. |
Linearity and Isotropicity. |
|
Calibration Extended (for all new PI-01,
PI-01V, PI-02, PI-03 and PI-04 units). |
Calibration of meter with probe. UK NPL (NIST) traceable. |
Linearity, Isotropicity and Frequency Correction
Factors |
|
Repair |
Repair and calibration of meter with probe. UK NPL (NIST) traceable |
Free during the warranty period. |