Table 1:
Meter/Probe Selection Table
|
Meter,
Probe Code |
Frequency
Range |
Field
Strength Range |
Time
Constants |
Notes |
|
RFP-04HF PI-03 |
2 MHz - 18 GHz |
0.5 – 800* V/m |
50 ms, 2 s, 14 s |
Stocked Model.
Worldwide
distribution |
|
RFP-04HF PI-02 |
1 MHz - 12.5 GHz |
0.5 – 800* V/m |
50 ms, 2 s, 14 s |
Stocked Model.
Worldwide
distribution |
|
RFP-04CE PI-01 |
0.2MHz - 3 GHz |
0.2 – 500* V/m |
50 ms, 2
s, 14 s |
Stocked Model.
Worldwide
distribution |
|
RFP-04LF PI-01LF |
50 KHz –
3 GHz |
0.4 – 500* V/m |
50 ms, 2 s, 14 s |
Extended
LF Range |
|
RFP-04UL PI-01UL |
0.2 MHz-
3 GHz |
1.0 – 800* V/m |
50 ms, 2 s, 14 s |
Extended
UL Range |
|
RFP-04F PI-01F |
0.2 MHz –3 GHz |
0.2 – 500* V/m |
5 ms, 2 s, 14 s |
Faster
Response Time for Pulsed Signals |
|
RFP-04E PI-01E |
0.2 MHz - 3 GHz |
0.2 – 500* V/m |
50 ms, 2 s, 14 s |
Environmental
Model. Contact
EMCTD for specification details. |
*Exact upper
field limit is specified for every unit.
Table 3: Accessories Selection Table
|
Name |
Description |
Notes |
|
Cable: Meter-Probe |
SMA/SMA 4-6 ft. |
Stocked,
Standard |
|
Cable: Remote Monitor Output |
3.5 mm one end -dual banana another
end, 6 ft. |
Stocked,
Special |
|
Tripod |
6Ó Nonmetal Tripod |
Stocked,
Standard. |
|
PCLK-01-1 |
Low Cost PC Link Kit (120 samples/sec). RS232
isolated serial data link for one channel with one isolating input module and
display software. |
Full system for data
streaming and display on PC for one RFP-04 unit. |
|
FOLK-01 |
Low Cost Fiber Optic Link for
PCLK-01-1. Fiber optic cable 10
meters. |
Makes
full system for data streaming and display on PC for one RFP-04 unit with fiber optic connection (requires PCLK-01-1). |
|
SF-01 |
Software driver for seamless
integration of Smart Fieldmeter with industry popular software. |
Available
for TILE EMC Software. |
|
DL-01-1 |
Portable data logging DMM with PC
Link (20 samples/sec). Logging
memory 5,400 data points.
Logging time interval 0.05 sec.-12 hours. |
DMM
with Optically Decoupled RS232 Link. Can also perform real time PC streaming
1 sample/sec. |
|
DL-01-2 |
Portable data logging DMM with PC
Link (20 samples/sec). Logging
memory 43,000 data points.
Logging time interval 0.05 sec.-12 hours. |
DMM
with Optically Decoupled RS232 Link. Can also perform real time PC streaming
1 sample/sec. |
|
DL-02 |
Portable data logging DMM with PC
Link. Has 33 readings memory for data storage operated by the user. |
DMM with Optically Decoupled RS232
Link. Can also perform real time PC
streaming 1 sample/sec. |
|
DL-03 |
Portable data logger with RS 232
output. Logging memory 8,192 data points. Logging time interval is set to 0.88 sec. until memory is
full (2 hours), then it is doubled, etc. |
Battery
logging operation for 1 year. |
|
DL-04 |
Portable data logger with RS 232
output. Logging memory 32,768 data points. Logging time interval from 2 sec. to 12 hours,
programmable. |
Battery
logging operation for 1 year. |
|
FC-01 |
Portable
frequency counter with frequency range 30 MHz-2.8 GHz. |
Measures pulsed GSM and cell phone
signals with RF pulse duration longer than 250 usec. |
Table 4: Services Selection Table
|
Name |
Description |
Notes |
|
Calibration Standard |
Calibration of meter with probe. NIST traceable. |
Linearity
and Isotropicity. |
|
Calibration Extended |
Calibration of meter with probe. NIST traceable. |
Linearity,
Isotropicity and Frequency Calibration Factors |
|
Repair |
Repair and calibration of
meter with probe. NIST traceable |
Free during the warranty period. |